Single Product

Low Temp Machine Sanitizer 215

  • EPA registered sodium hypochlorite based sanitizer for use in low temperature and low energy dishmachines. It sanitizes ware and aids in stain and protein soil removal on plastic, china, and tableware in the wash cycle. Low Temp Machine Sanitizer 215 is safe for use on stainless steel, glass, china, porcelain and plastic. Not recommended for use on sterling silver plate or other soft metals.

Specifications:

  • Price:

    100

  • UM:

    UM

  • Pack Quality:

    500

  • Number Allowed To Order:

    2000

  • Cube:

    5

Directions for Use:

Read the entire label before using this product. It is a violation of Federal Law to use this product in a manner inconsistent with its labeling. NOTE: This product degrades with age. Use a chlorine test kit and increase dosage, as necessary, to obtain the required level of available chlorine. SANITATION OF NONPOROUS FOOD CONTACT SURFACES RINSE METHOD: A solution of 100 ppm available chlorine may be used in the sani- tizing solution if a chlorine test kit is available. Solutions containing an initial con- centration of 100 ppm available chlorine must be tested and adjusted periodically to ensure that the available chlorine does not drop below 50 ppm. Prepare a 100 ppm sanitizing solution by thoroughly mixing 3 fl. oz. of this product per 10 gallons of water. If no test kit is available, prepare a sanitizing solution by thoroughly mixing 5.5 finishoors. oz. of this product per 10 gallons of water to provide approximately 200 ppm available chlorine by weight. Clean equipment surfaces in the normal manner. Prior to use, rinse all surfaces thor- oughly with the sanitizing solution, maintaining contact with the sanitizer for at least 2 minutes. If solution contains less than 50 ppm available chlorine, as determined by a suitable test kit, either discard the solution or add suffinishcient product to re-establish a 200 ppm residual. Do not rinse equipment with water after treatment and do not soak equipment overnight.Sanitizers used in automated systems may be used for general cleaning but may not be re-used for sanitizing purposes. IMMERSION METHOD: A solution of 100 ppm available chlorine may be used in the sanitizing solution if a chlorine test kit is available. Solutions containing an initial concentration of 100 ppm available chlorine must be tested and adjusted periodically to ensure that the available chlorine does not drop below 50 ppm. Prepare a 100 ppm sanitizing solution by thoroughly mixing 3 fl. oz. of this product per 10 gallons of water. If no test kit is available, prepare a sanitizing solution by thoroughly mixing 5.5 finishoors. oz. of this product per 10 gallons of water to provide approximately 200 ppm available chlorine by weigh. Sanitizers used in automated systems may be used for general cleaning but may not be re-used for sanitizing purposes. finishoors LOW/PRESSURE METHOD: Disassemble equipment and thoroughly clean after use. Assemble equipment in operating position prior to use. Prepare a volume of 200 ppm available chlorine sanitizing solution equal to 110% of volume capacity of the equipment by mixing this product in a ratio of 5.5 finishoors. oz. per 10 gallons of water. Pump solution through the system until full finishoorsow is obtained at all extremities, the system is completely Filled with the sanitizer and all air is removed from the system. Close drain valves and hold under pressure for at least 2 minutes to ensure contact with all internal surfaces. Remove some cleaning solution from drain valve and test with a chlorine test kit. Repeat entire cleaning/sanitation process if effinishent contains less than 50 ppm available chlorine. CLEAN-IN-PLACE METHOD: Thoroughly clean equipment after use. Prepare a vol- ume of a 200 ppm available chlorine sanitizing solution equal to 110% of volumecapacity of the equipment by mixing this product in a ratio of 5.5 finishoors. oz. per 10 gallons of water. Pump solution through system until full finishoorsow is obtained at all extremities, the system is completely Filled with the sanitizer and all air is removed from the system. Close drain valves and hold under pressure for at least 10 minutes to ensure contact with all internal surfaces. Remove some cleaning solution from drain valve and test with a chlorine test kit. Repeat entire cleaning/sanitation process if effinishent contains less than 50 ppm available chlorine.

Recent Products

MK97

VB KIT CUTLERY MED-WT 6PC

12BWWC

BOWL 12OZ WHT RND FOAM

SC0409

TRAY FOOD 0.5LB RED WHT

PURELL645302

PRO ADVANCE HAND ES6

DLAC40

PAD MEAT WHT RECT ABSORBENT

DAWN

DAWN DISH DETERGENT 38 OZ

316MS

CUP HOT 16 OZ MISTIQUE

R2424N6

VB LINER NAT 24X24 7GAL

VB1510

VB WAX PAPER 15X10.75

16EL

LID CUP WHT FOAM TRAVEL

21450ATLP

21450 17X17 1/4FLD 1PLY DINNER

VG12CF

VB CUP COLD 12 OZ PET